The mobile self-cleaning filter housing is particularly suited to high particle concentrations and abrasive dusts. It is fitted with HEPA filters ensuring a high filtration efficiency.

TECHNICAL SPECIFICATIONS
Dimensions: 1,600 x 1,900 x 790 mm
Max. air flow: 6,000 mÂł/h
Max. permissible pressure: ± 6,000 Pa
Max. permissible temperature: 90°C
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Robust stainless steel filter housing in a gas-tight version complying with the leak-tightness requirements of DIN 25 496, to accommodate HEPA filter elements together with a secondary safety filter.
HEPA filter elements leak-tested.
Contamination-free filter replacement thanks to bag-in/bag-out technology.
Contamination-free dust discharge into a service bag.
Good separation of agglomerated dusts
Suitable for various types of dust, in particular critical particles
1.00 € 1.0 EUR
Stationary Self-Cleaning Filter Housing
The stationary self-cleaning filter housing is particularly suited to high particle concentrations and abrasive dusts. It is fitted with HEPA filters ensuring a high filtration efficiency.

TECHNICAL SPECIFICATIONS
Dimensions: 1,600 x 1,900 x 790 mm
Max. air flow: 10,000 mÂł/h
Max. permissible pressure: ± 6,000 Pa
Max. permissible temperature: 90°C
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Robust stainless steel filter housing in a gas-tight version complying with the leak-tightness requirements of DIN 25 496, to accommodate HEPA filter elements together with a secondary safety filter.
HEPA filter elements leak-tested.
Contamination-free filter replacement thanks to bag-in/bag-out technology.
Contamination-free dust discharge into a service bag.
Good separation of agglomerated dusts
Suitable for various types of dust, in particular critical particles
1.00 € 1.0 EUR
100% CBRN Filter Housing
The 100% CBRN filter housing is recommended for the adsorption of high-risk pollutants requiring a long residence time in filter systems. With the EWS-type filter system, the loaded activated carbon is replaced 100% and changed using safe-change technology.

TECHNICAL SPECIFICATIONS
Nominal air flow rate: 30,000 mÂł/h
Max. permissible pressure differential: 10,000 Pa
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa
Air flow velocity: < 0.5 m/s

TECHNICAL DATA
Easy handling of the Safe Change technology.
Compact and versatile design.
Simple, efficient and clean filling procedure.
High level of protection for the environment and for operating personnel.
1.00 € 1.0 EUR
Bulk Activated Carbon CBRN Filter Housing
The bulk activated carbon CBRN filter housing is recommended for the adsorption of high-risk pollutants requiring a long residence time in filter systems. It features a divided activated carbon bed, which reduces activated carbon consumption by 50% compared with conventional adsorption filter systems.

TECHNICAL SPECIFICATIONS
Nominal air flow rate: 20,000 mÂł/h
Max. permissible pressure differential: 10,000 Pa
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa
Air flow velocity: < 0.5 m/s

TECHNICAL DATA
Easy handling of the Safe Change technology. Compact and versatile design. Simple, efficient and clean filling procedure. High level of protection for the environment and for operating personnel.
Whereas with the CFH classic filtration system 100% of the loaded carbon is changed in a single operation, the loading capacity of the carbon is used more efficiently with the CFH hightec filtration system. There, only the first half of the filter bed is changed, while the relatively unloaded second half of the filter bed takes the place of the first half. Only the second half of the filter bed is then filled with fresh carbon.
1.00 € 1.0 EUR
CBRN Carbon Filter Cassette
The CBRN carbon filter cassette is recommended and suited to the separation of airborne particles, aerosols and odour nuisance in the nuclear industry, research, industry, etc.

TECHNICAL SPECIFICATIONS
Filter dimensions: 610 x 610 x 292 mm
Max. air flow: 1,500 mÂł/h
Filling volume: 75 L
Weight: 36 kg

TECHNICAL DATA
Using this type instead of disposable filter cells considerably reduces waste. Only the filter media and the seals need to be changed.
The filter element can be filled with any type of medium. Selecting the right filter medium is essential in order to achieve a high efficiency.
1.00 € 1.0 EUR
Custom Filtration Solution Container
The custom filtration solution container is supplied as a supply air or extract air ventilation unit. It can be fully fitted with fans, filter banks, shut-off dampers, control and sampling systems, or with customised equipment on request.

TECHNICAL SPECIFICATIONS
Customisable to your requirements
1.00 € 1.0 EUR
Filter Wall
A customisable filter wall with a wide range of filter elements to suit your requirements.

TECHNICAL SPECIFICATIONS
According to your technical requirements.
1.00 € 1.0 EUR
Classic HEPA Filter Housing
The Classic HEPA filter housing is designed specifically for the ventilation of sensitive areas in the nuclear, chemical and pharmaceutical industries and in laboratories, where radioactive, toxic or pathogenic substances must be filtered out of the air in order to protect the environment, production or operator health.

The Classic HEPA filter housing has been developed to meet stringent requirements in terms of safety and filtration efficiency. It can be adapted to a wide range of filtration duties and can be configured in various ways, making it a versatile filter housing.

TECHNICAL SPECIFICATIONS
Max. nominal air flow rate: 24,000 mÂł/h
Permissible differential pressure: ± 6,000 Pa
Max. temperature: 90°C
Maximum internal / external leakage to DIN 25 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Compact stainless steel frame
Seal compliant with DIN 25496 for each filter element.
1.00 € 1.0 EUR
Hightec HEPA Filter Housing
The Hightec HEPA filter housing is designed specifically for ventilation in sensitive areas of the nuclear, chemical, decommissioning and pharmaceutical industries, where radioactive, toxic or pathogenic substances must be filtered out of the air in order to protect the environment, production or operator health.

The Hightec HEPA filter housing meets the stringent requirements placed on filtration systems in terms of safety and filtration efficiency. It can be adapted to almost any demanding filtration duty and can be configured in various ways.

The Hightec HEPA filter housing can be customised for all more demanding filtration requirements.

TECHNICAL SPECIFICATIONS
Nominal air flow rate: 48000 mÂł/h
Permissible differential pressure: ± 6,000 Pa
Max. temperature: 90°C
Maximum internal / external leakage to DIN 24 496: < 3 · 10-5 of the nominal air flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Compact stainless steel frame
Seal compliant with DIN 25496 for each filter element.
1.00 € 1.0 EUR
Mobile HEPA Filter Housing
The mobile HEPA filter housings are supplied ready for use for temporary uses and applications in order to filter the air. They are particularly useful during maintenance operations on HVAC systems.

The mobile HEPA filter housing combines pre-filter and HEPA filter stages with an integrated fan.

TECHNICAL SPECIFICATIONS
MFU Classic dimensions: 780 x 1,580 x 1,065 mm
MFU Hightec dimensions: 915 x 1,915 x 1,605 mm
Volume flow rate: 3,000 mÂł/h
Max. permissible pressure difference: ±6,000 Pa
Max. permissible operating temperature: 70 °C
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal volume flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Air inlet and outlet section
Robust filter housing
Gas-tight circular dampers
Fan section
Silencer section
Control system
1.00 € 1.0 EUR
Nuclear HEPA Filter Housing
The nuclear HEPA filter housing is used to accommodate HEPA filter elements, either individually or in combination with a pre-filter.

TECHNICAL SPECIFICATIONS
Dimensions: 610 x 610 x 50 mm or 610 x 610 x 150 mm
Volume flow rate: 3,000 mÂł/h
Max. permissible pressure difference: ±6,000 Pa
Max. permissible operating temperature: 90 °C
Filter housing leak-tightness acc. to DIN 24 496: < 3 · 10-5 of the nominal volume flow rate at Δp = 2,000 Pa

TECHNICAL DATA
Robust stainless steel filter housing in a gas-tight welded design in accordance with the leak-tightness requirements of DIN 25 496, for fine dust and HEPA filter elements
Contamination-free filter replacement thanks to bag-in/bag-out technology
1.00 € 1.0 EUR
Single-Cell HEPA Filter Housing
The single-cell HEPA filter housing is installed in ventilation systems in order to accommodate HEPA filter elements.

TECHNICAL SPECIFICATIONS
HEPA filter – Filter element dimensions: 610 x 610 x 150 mm or 610 x 610 x 292 mm
Nominal air flow rate per housing: 3400 mÂł/h
Housing height: 473 mm or 615 mm
Weight without filter elements: 32 kg
Max. temperature: 90°C
1.00 € 1.0 EUR