0
Cleanroom Qualification
Nuclear Ventilation Solutions
Our Commitments
Careers
Contact us
English
English
Français
0
Cleanroom Qualification
Nuclear Ventilation Solutions
Our Commitments
Careers
Contact us
English
English
Français
Products
Nuclear Ventilation Components
Fire Protection
STAURATEC Lilly
STAURATEC Lilly
Fire Protection
Smoke Extraction
Fire Dampers
Intumescent Fire Damper 120 min / 500 Pa
The 120 min / 500 Pa intumescent fire damper withstands seismic events and is perfectly suited to applications requiring high pressures and high air flows.
TECHNICAL SPECIFICATIONS
Min. size: 200 x 200 x 450 mm
Max. size: 1000 x 1000 x 450 mm
Max. air velocity 20 m/s
Max. pressure difference 500 Pa
TECHNICAL DATA
CE certified to EN 15650
Tested to EN 1366-2
Classified to EN 13501-3+A1
Fire resistance EIS 120
External casing leakage class C,
Internal leakage class 2 to EN 1751
Corrosion resistant to EN 15650
Cycling test to class C10,000 to EN 15650
Damper with mechanical, electrical, pneumatic or electromechanical actuation. Pneumatic control makes direct connection to the SWAGELOK system straightforward.
Plain bearings - maintenance-free design withstanding high-level seismic loads
Earthquake resistant (high resistance)
Guaranteed 40-year service life
1.00
€
1.0
EUR
Intumescent Fire Damper 180 min / 500 Pa
The Intumescent Fire Damper 180 min / 500 Pa withstands seismic events and is perfectly suited to applications requiring high pressures and high air flows.
TECHNICAL SPECIFICATIONS
Min. dimensions: 150 x 150 mm
Max. dimensions: 1,500 x 800 mm
Max. air velocity 12 m/s
Max. pressure differential 500 Pa
TECHNICAL DATA
Fire resistance up to EI 180 S
Leak-tightness to EN 1751, class C, and through the blade, class 2
Damper operation mechanical or by means of an actuator
Corrosion resistance compliant with EN 15650
Cycle test C10000 or Cmod (depending on actuator type) compliant with EN 15650
CE certification compliant with EN 15650
Tested in compliance with EN 1366- 2
Classified in compliance with EN 13501- 3+A1
Design certified for explosion-risk environments
1.00
€
1.0
EUR
Intumescent Fire Damper 120 min / 1500 Pa
The Intumescent Fire Damper 120 min / 1500 Pa withstands seismic events and is perfectly suited to applications requiring high pressures and high air flows.
TECHNICAL SPECIFICATIONS
Min. dimensions: 200 x 200 x 600 mm
Max. dimensions: 1,000 x 1,000 x 600 mm
Max. air velocity 16 m/s
Max. pressure differential 1,500 Pa
TECHNICAL DATA
Fire resistance EI 120 S
Galvanised steel, painted carbon steel or stainless steel
Seismic resistance defined to RRS (DBE, APC)
CE certification compliant with EN 15650
Tested in compliance with EN 1366- 2
Classified in compliance with EN 13501- 3+A1
Minimum service life 30 years (maintenance-free design)
1.00
€
1.0
EUR
Intumescent Fire Damper 180 min / 5000 Pa
The Intumescent Fire Damper 180 min / 5000 Pa is a product developed to meet the requirements of special, highly technical projects according to their fields of application.
The Intumescent Fire Damper 180 min / 5000 Pa was nominated for best product in the “safety and innovation” category at the WNE 2023 exhibition
TECHNICAL SPECIFICATIONS
Dimensions: min. Ø200, max. 800 mm (circular design only, extension connection to square ductwork possible)
Stainless steel – casing thickness 3 – 6 mm, welded construction with pickling and passivation
Max. air velocity 35 m/s
Tested pressure differential 23,000 Pa
Seismically resistant (high resistance)
Pressure tightness – blade closed max. 14 l/m²/min at 1.1 bar (tested on both sides of the blade)
Operates at temperatures up to 220 °C
Safe cycles with no loss of leak-tightness / fire resistance of at least 20,000
Usable in a magnetic field up to 126 mT
Radiation resistance up to 100 kGy
Suitable for explosion-risk areas class II 3 / 3G c IIB + H2 TX
TECHNICAL DATA
Can be installed in any position within a rigid wall or ceiling, on solid walls, on ceilings with additional insulation and in ductwork installations with rock wool insulation
Decontaminable
Guaranteed 40-year service life
Certified for low voltage and electromagnetic compatibility
The IP rating of the actuators / pneumatic actuators / limit switches is 65
Can be used as a high leak-tightness and pressure-resistant fire damper, a pressure-tight damper or a fire damper
Electric actuator (e.g. AUMA, Bernard Controls, SIPOS) or pneumatic actuator (STASTO-VALBIA), with limit switches (e.g. Petercem, Telemechanique, Honeywell)
Tested to EN 1366-2, classified to EN 13501-3, CE certified to EN 15650
Fire rating EI 180 ve, ho (i ↔ o) S
1.00
€
1.0
EUR
Single-Compartment Circular Smoke Control Damper
The single Single-Compartment Circular Smoke Control Damper is a damper in smoke extraction duct systems. The dampers are designed to remove heat and combustion products (e.g. smoke) from a single fire compartment.
The damper is operated by an actuating mechanism. The dampers can be installed in different duct sizes with respect to the field of direct application to EN 1366-9.
TECHNICAL SPECIFICATIONS
Multiple dimensions, diameter 100 to 630 mm
The dampers are designed for smoke extraction duct systems with a max. negative pressure of 1,500 Pa or
max. positive pressure of 500 Pa.
The dampers are designed for a maximum air velocity of 15 m/s.
The temperature at the installation location is permitted within a range of -30°C to +50°C.
TECHNICAL DATA
The dampers are suitable for systems free from abrasive, chemical and adhesive particles.
The dampers are designed for macroclimatic zones with a mild climate to EN 60 72133.
The dampers can be installed in different duct sizes with respect to the field of direct application to EN 1366-9.
Compliant with EN 1363-1, parts A.1 and A.2, EN 1366-2, part 13 and EN 1366-10, part 9.
1.00
€
1.0
EUR
Single-Compartment Rectangular Smoke Control Damper
The single Single-Compartment Rectangular Smoke Control Damper is a damper in smoke extraction duct systems. The dampers are designed to remove heat and combustion products (e.g. smoke) from a single fire compartment.
The damper is operated by an actuating mechanism. The dampers can be installed in different duct sizes with respect to the field of direct application to EN 1366-9.
TECHNICAL SPECIFICATIONS
Multiple dimensions, 180 x 180 to 1,600 x 1,000 mm
The dampers are designed for smoke extraction duct systems with a max. negative pressure of -1,000 Pa or max. positive pressure of 500 Pa.
The dampers are designed for a maximum air velocity of 15 m/s
The max. permitted temperature is between -30°C and +50°C
TECHNICAL DATA
Compliant with EN 1363-1, parts A.1 and A.2, EN 1366-2, part 13 and EN 1366-10, part 9. Declaration of performance no. PM/SEDS/01/21/1
In the event of fire, the ventilation system opens the damper provided in order to remove the combustion products and heat from that section.
The dampers are designed for installation with a horizontal blade axis. The flow direction must be directed from the actuation side.
1.00
€
1.0
EUR
Multi-Compartment Single-Blade Smoke Control Damper
The Multi-Compartment Single-Blade Smoke Control Damper is a damper in smoke extraction duct systems. The dampers are designed to remove heat and combustible products (e.g. smoke) from a fire compartments. In the event of fire, the Smoke and Fire ventilation system opens the damper in the affected section and removes the combustion products and heat from that section.
The damper blade is controlled by an electric actuating mechanism.
The dampers are fire resistant and are intended for manually or automatically activated systems.
The dampers are designed for use in fire compartments that may be connected to smoke
extraction ducts (tested to EN 1366-8) or they may be installed in or on the fire compartment construction.
TECHNICAL SPECIFICATIONS
Multiple dimensions: 180 x 180 to 1,600 x 1,000 mm
Maximum air velocity 15 m/s
Max. negative pressure -1,500 Pa or max. positive pressure 500 Pa.
The temperature at the installation location is permitted within a range of -30°C to +50°C
TECHNICAL DATA
The dampers can be installed in an arbitrary position (horizontal or vertical blade axis).
The dampers are designed for macroclimatic zones with a mild climate to EN 60 721-3-3.
CE certified acc. to EN 12101-8
Tested in compliance with EN 1366-10
Classified acc. to EN 13501-4+A1
Fire resistance to Tab. 1.2.1
External casing leakage class C, internal leakage min. class 2 acc. to EN 1751
Cycle testing to class Cmod acc. to EN 12101-8
Certificate of constancy of performance no. 1391-CPR-2021/0008
Declaration of Performance No. PM/SEDM/01/21/4
Hygiene assessment of fire dampers – Report no. 1.6/pos/19/19c
1.00
€
1.0
EUR
Multi-Compartment Multi-Blade Smoke Control Damper
The Multi-Compartment Multi-Blade Smoke Control Damper is a closure in smoke extraction duct devices. In the event of fire, the smoke and heat exhaust system opens the dampers in the affected section, thereby allowing the extract fans to remove the combustion products and heat from the areas at risk.
The damper is fire resistant and is designed for automatically or manually activated systems.
Smoke control dampers are intended for use in spaces comprising several fire compartments, which may be connected by a smoke extraction duct tested to EN 1366-8 or may be installed in the fire compartment construction.
TECHNICAL SPECIFICATIONS
Multiple dimensions: 200 x 430 to 1,200 x 2,030 mm
Maximum air flow velocity 12 m/s
Maximum negative pressure up to 1,000 Pa or positive pressure up to 500 Pa
Temperature limit from -30°C to 50°C.
TECHNICAL DATA
The dampers are suitable for installation in a vertical position, with the blade axis horizontal.
The dampers are designed for weather-protected environments with class 3K5 climatic conditions, without condensation, frost or ice formation, and without water from sources other than rain
Tested to EN 1366-10
Classified to EN 13501-4 + A1
Fire resistance to Tab. 1.3.1
Pressure class 2 (negative pressure 1,000 Pa / positive pressure 500 Pa)
Leak-tightness to EN 1751
Cmod cycling to EN 12101-8
Certificate no. 1391-CPR-2021/0009
Declaration of performance no. PM/SEDM-L/01/21/1
1.00
€
1.0
EUR
Multi-Compartment Rectangular Smoke Control Damper
The Multi-Compartment Rectangular Smoke Control Damper is a shut-off device in smoke extraction duct systems. The dampers are designed to remove heat and combustible products (e.g. smoke) from the affected fire compartments. In the event of fire, the ventilation system opens the damper in the affected section and removes the combustion products and heat.
The damper blade is controlled by an electric actuating mechanism. The dampers are fire resistant and are intended for automatically activated systems. Dampers can be installed in the fire compartment construction.
TECHNICAL SPECIFICATIONS
Multiple dimensions: 160 x 180 to 1,500 x 800 mm
Maximum air velocity 15 m/s
Max. negative pressure -1,500 Pa or max. positive pressure 500 Pa.
Max. permitted temperature from -30°C to +50°C.
TECHNICAL DATA
The dampers can be installed in an arbitrary position (horizontal or vertical blade axis).
The dampers are designed for macroclimatic zones with a mild climate to EN 60 721-3-3.
CE certified acc. to EN 12101-8
Tested in compliance with EN 1366-10
Classified acc. to EN 13501-4+A1
Fire resistance to Tab. 1.2.1. and 1.2.2.
External casing leakage class min. C acc. to EN 175
1.00
€
1.0
EUR
Multi-Compartment Circular Smoke Control Damper
The Multi-Compartment Circular Smoke Control Damper is a shut-off device in smoke extraction duct systems. The dampers are designed to remove heat and combustible products (e.g. smoke) from the affected fire compartments. In the event of fire, the ventilation system opens the damper in the affected section and removes the combustion products and heat.
The damper blade is controlled by an electric actuating mechanism. The dampers are fire resistant and are intended for automatically activated systems. Dampers can be installed in the fire compartment construction
TECHNICAL SPECIFICATIONS
Multiple dimensions: diameter 180 to 630 mm
Maximum air velocity 15 m/s
Max. negative pressure -1,500 Pa or max. positive pressure 500 Pa.
Max. permitted temperature from -30°C to +50°C.
TECHNICAL DATA
The dampers can be installed in an arbitrary position (horizontal or vertical blade axis).
The dampers are designed for macroclimatic zones with a mild climate to EN 60 721-3-3.
CE certified acc. to EN 12101-8
Tested in compliance with EN 1366-10
Classified acc. to EN 13501-4+A1
Fire resistance to Tab. 1.2.1. and 1.2.2.
External casing leakage class min. C acc. to EN 175
1.00
€
1.0
EUR